Transformers & Chokes

Transformer - Hammond, Low Voltage / Filament, Open, 16 VCT
Special Order Item
  • Open style, chassis mount transformers with a 115V 60Hz primary and a 16V center tapped secondary.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 100 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 100V center tapped secondary.
Please Log In to view prices
Transformer - Fender®, Output, Hot Rod Deluxe and Blues Deluxe
Fender Original Hot Rod Deluxe and Blues Deluxe output transformer. 40 watts. Equivalent to #050438.
Please Log In to view prices
Transformer - Fender, Power, for Deluxe Reverb 120V
Genuine Fender power transformer designed for use in the ‘65 Deluxe Reverb as well as the ‘68 Deluxe. Made to original fender specifications. 120V Primary
Please Log In to view prices
Transformer - Output, 5W, 5k & 8k Primary Options, Upgrade for Fender® Champ
Output transformer upgrade for the Fender® part numbers 125A35A, 125A3A, and 022905 as used in the:
  • Bronco (AA764, AB764, Blackface, Silverface)
  • Champ (Tweed, 5C1, 5E1, 5F1, AA764, Blackface, Silverface, Vibro Blackface)
  • Harvard (6G10)
  • Princeton (Tweed, 5B2, 5C2, 5D2, 5E2, 5F2, 5F2A)

This upgraded transformer features both 4 ohm and 8 ohm taps on the secondary. The primary has two impedance options for lower voltage (5K) and higher voltage (8k) models.
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 15V / 30V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 30 V series, 15 V parallel secondary.
Please Log In to view prices
Transformer - Hammond, Plate & Filament or Bias, 6.3 V auxiliary
  • Primary 115 VAC, 60 Hz.
  • Designed for small power or bias supplies, test equipment, preamps etc.
  • Models P-T261C6, P-T261E6, and P-T261G6 can also be used with full wave C.T. rectifiers.
  • Economical , two hole, channel bracket, chassis mount.
  • Minimum 5" long leads.
  • Convenient 6.3 filament/auxiliary winding.
Please Log In to view prices
Transformer - Hammond, Power, Low voltage, 16V/3A
Specifications:
  • Size: 48 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 16V @ 3 A
  • Secondary VAC RMS Parallel: 8V @ 6 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra pr
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 24 V no tap
Special Order Item
Open style, chassis mount transformers with a 117V 50/60Hz primary and a 24V secondary.
Please Log In to view prices
Transformer - Hammond, Isolation, 115V
  • Primary 115VAC, 60 Hz.
  • Secondary 115VAC
  • Electrostatic shield between primary & secondary
  • Connection by flexible leads, 8" minimum length
  • Perfect for circuit isolation or "Classic" bias power supply
  • CSA certified (209651)
  • Remember - These units do NOT convert line frequency
Please Log In to view prices
Transformer - Hammond, Universal Single Ended
  • Designed for general purpose or replacement use (not Hi-Fi), in single ended, tube output circuits.
  • Frequency response: 100 Hz. - 15 Khz (± 1db max. - ref. 1 Khz). (For full frequency response (20 Hz. to 20 Khz.) - see P-T1627SE).
  • For push-pull output use, see P-T125A - optimized for push-pull tube output circuits.
  • Open style with minimum 12" long primary & secondary leads leads.
  • All sizes use butt stacked cores (using 29M6 steel) with an air gap, to reduce D.C. core saturation.
  • Primary impedance range from 2,500 to 10,000 Ohms.
  • Secondary impedance range from 4 to 32 Ohms.



Part No.
Audio Power
Max D.C. Bias
Dimensions (Inches)


A
B
C
D
E
G Mtg.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 5 VCT
  • Open style, chassis mount transformers with a 115V 60Hz primary and a 5V center tapped secondary.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 42 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 42V center tapped secondary.
Please Log In to view prices
Transformer - Marshall, Output, for JTM45
Special Order Item
Genuine Marshall™ output transformer for JTM45.
Please Log In to view prices
Transformer - Hammond, Guitar Amplifier, replacement for Marshall
  • Replacements for Marshall amps
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Please Log In to view prices
Transformer - Reverb Driver, for Fender® Amps, 125A20B Replacement
Replacement reverb driver transformer for the Fender® part numbers 125A20B, 022921, and 037099. This is the standard reverb driver transformer used in most Fender amps that use a 12AT7 and transformer driven 4AB3C1B tank. Found in countless Fender® models including original and reissues of the following:
  • Fender Princeton Reverb
  • Fender Deluxe Reverb
  • Fender Vibrolux Reverb
  • Fender Pro Reverb
  • Fender Super Reverb
  • Fender Twin Reverb
  • Fender Quad Reverb
  • Fender Super Six Reverb
  • Fender Vibrosonic
  • Many others
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 22V / 44V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 44 V series, 22 V parallel secondary.
Please Log In to view prices
Transformer - Hammond, Guitar Amplifier, replacement for Fender, 120 V
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • See P-T290-FENDER-120-UP for upgraded 120 V transformers, P-T290-FENDER-240 for 240 V transformers

Warning: Not all amplifier models of the same name use the same transformer model.
Please Log In to view prices
Transformer - Hammond, Power, Low voltage, 6.3V/6A
Specifications:
  • Size: 37.8 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 6.3V @ 6 A
  • Secondary VAC RMS Parallel: 3.15V @ 12 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for e
Please Log In to view prices
Transformer - Hammond, Audio Broadcast Quality, 850A Series
Deep-drawn steel case with tin plated finish, with two convenient 6-32 mounting studs with mounting hardware. Sealed case and wax potted core internally for stable characteristics and long life. Wide frequency response +/- 0.5 db max. from 20 Hz. to 20 Khz. (except units over 5K ohms impedance, may be down 1 db @ 20 Khz.) Insertion loss of apx. 1 db.
Please Log In to view prices
Transformer - Hammond, Power, Low V Primary / Secondary, 5V/3A
Specifications:
  • Size: 15 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 5V @ 3 A
  • Secondary VAC RMS Parallel: 2.5V @ 6 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra p
Please Log In to view prices
Transformer - Audio Interstage, 10 mA
Equivalent to Stancor A53-C. 1:3 ratio overall. Center tapped secondary may be used for push-pull grids.Specifications Max. Primary Current: 10 mA Impedance Primary to Secondary (Ohms): 10,000 to 90,000
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Enclosed, 36 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 36 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 33 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 33V center tapped secondary.
Please Log In to view prices