Transformers & Chokes
Transformer - Hammond, Low Voltage / Filament, Enclosed, 25 VCT
- Primary 115 VAC, 60 Hz.
- Secondary 25 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
Please Log In to view prices
Transformer - Hammond, Power, Low Voltage PC Mount
Size: 48 VA
Secondary Series: 40V C.T. @ 1.2A
Secondary Parallel: 20V @ 2.4 A
Features:
Secondary Series: 40V C.T. @ 1.2A
Secondary Parallel: 20V @ 2.4 A
Features:
- Low profile mounting, dual - split bobbin design.
- Low primary to secondary coupling, balanced windings, no electrostatic shield required and low EMF radiation due to semi-toroidal design.
- Universal dual primary 115/230V - 50/60 Hz.
- High insulation - Hipot of 1,750V RMS.
- Class B insulation - 130 degrees C.
- C UL US recognized.
Please Log In to view prices
Transformer - Hammond, Plate & Filament or Bias, 12.6V auxiliary
- Primary 115 VAC, 60 Hz.
- Designed for small power or bias supplies, test equipment, preamps etc.
- Economical , two hole, channel bracket, chassis mount.
- Minimum 5" long leads.
- Convenient 12.6 filament/auxiliary winding.
Please Log In to view prices
Transformer - Hammond, Power, Low voltage, 14V/0.5A
Specifications:
Features:
- Size: 7 VA
- Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
- Secondary VAC RMS Series: 14V @ 0.5 A
- Secondary VAC RMS Parallel: 7V @ 1 A
Features:
- Primary 117/234 VAC, 50/60 Hz.
- Dual secondaries
- Secondaries can be used as; a center tapped secondary, parallel connected or used individually
- Units are designed for use with all windings engaged.
- Open style.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees, C) for extra p
Please Log In to view prices
Transformer - Hammond, Power, Low voltage, 36V/0.5A
Specifications:
Features:
- Size: 18 VA
- Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
- Secondary VAC RMS Series: 36V @ 0.5 A
- Secondary VAC RMS Parallel: 18V @ 1 A
Features:
- Primary 117/234 VAC, 50/60 Hz.
- Dual secondaries
- Secondaries can be used as; a center tapped secondary, parallel connected or used individually
- Units are designed for use with all windings engaged.
- Open style.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees, C) for extra
Please Log In to view prices
Transformer - Hammond, Power, Low voltage, 14V/1A
Specifications:
Features:
- Size: 14 VA
- Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
- Secondary VAC RMS Series: 14V @ 1 A
- Secondary VAC RMS Parallel: 7V @ 2 A
Features:
- Primary 117/234 VAC, 50/60 Hz.
- Dual secondaries
- Secondaries can be used as; a center tapped secondary, parallel connected or used individually
- Units are designed for use with all windings engaged.
- Open style.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees, C) for extra pr
Please Log In to view prices
Transformer - Hammond, Power, Low voltage, 48V/1A
Specifications:
Features:
- Size: 48 VA
- Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
- Secondary VAC RMS Series: 48V @ 1 A
- Secondary VAC RMS Parallel: 24V @ 2 A
Features:
- Primary 117/234 VAC, 50/60 Hz.
- Dual secondaries
- Secondaries can be used as; a center tapped secondary, parallel connected or used individually
- Units are designed for use with all windings engaged.
- Open style.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees, C) for extra p
Please Log In to view prices
Transformer - Hammond, Power, Low V Primary / Secondary, 5V/3A
Specifications:
Features:
- Size: 15 VA
- Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
- Secondary VAC RMS Series: 5V @ 3 A
- Secondary VAC RMS Parallel: 2.5V @ 6 A
Features:
- Primary 117/234 VAC, 50/60 Hz.
- Dual secondaries
- Secondaries can be used as; a center tapped secondary, parallel connected or used individually
- Units are designed for use with all windings engaged.
- Open style.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees, C) for extra p
Please Log In to view prices
Transformer - Hammond, Power, Low voltage, 12.6V/4A
Specifications:
Features:
- Size: 50.4 VA
- Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
- Secondary VAC RMS Series: 12.6V @ 4 A
- Secondary VAC RMS Parallel: 6.3V @ 8 A
Features:
- Primary 117/234 VAC, 50/60 Hz.
- Dual secondaries
- Secondaries can be used as; a center tapped secondary, parallel connected or used individually
- Units are designed for use with all windings engaged.
- Open style.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees, C) for ex
Please Log In to view prices
Transformer - Hammond, Power, Low voltage, 6.3V/6A
Specifications:
Features:
- Size: 37.8 VA
- Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
- Secondary VAC RMS Series: 6.3V @ 6 A
- Secondary VAC RMS Parallel: 3.15V @ 12 A
Features:
- Primary 117/234 VAC, 50/60 Hz.
- Dual secondaries
- Secondaries can be used as; a center tapped secondary, parallel connected or used individually
- Units are designed for use with all windings engaged.
- Open style.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees, C) for e
Please Log In to view prices
Transformer - Hammond, Line Step Up Isolation, Toroidal, 500 VA
Capacity: 500 VA
Dimensions: 9" long by 6" wide by 4" height
Features:
Dimensions: 9" long by 6" wide by 4" height
Features:
- Primary 120VAC, 50/60 Hz., Secondary 240VAC.
- Provides circuit isolation.
- Toroidal transformer for high isolation, low noise, light weight cool operation and low profile.
- 50 or 60 Hz.
Please Log In to view prices
Transformer - Hammond, High Voltage Plate, 115 VAC, 50 / 60 Hz
- Primary 115 VAC, 50 / 60 Hz.
- At 2,000 VAC and above, secondary leads are through rubber bushings
- Units can be run full wave bridge or full wave C.T.
- V.A. is a C.C.S. rating
- Current ratings are CCS (Continuous Commercial Service) & ICAS ratings (Intermittent Commercial or Amateur Service).
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Class A insulation (105 degrees C).
- Hi-Pot test at a minimum of twice secondary voltage
- Conservative designs - CSA certified (209651).
Please Log In to view prices
Transformer - Hammond, Audio Broadcast Quality, 800A Series
Deep-drawn steel case with tin plated finish, with two convenient 6-32 mounting studs with hardware. Includes wire leads (minimum length of 4"). Frequency response +/- 0.5 db max. from 50 Hz. to 15 Khz. Insertion loss of apx. 1 db. Maximum power level +15 dbm. (except 841A, 842A & 844A which are +20 dbm) with specified characteristics, or higher levels with reduced low frequency performance.
Please Log In to view prices
Transformer - Hammond, Audio Broadcast Quality, 850A Series
Deep-drawn steel case with tin plated finish, with two convenient 6-32 mounting studs with mounting hardware. Sealed case and wax potted core internally for stable characteristics and long life. Wide frequency response +/- 0.5 db max. from 20 Hz. to 20 Khz. (except units over 5K ohms impedance, may be down 1 db @ 20 Khz.) Insertion loss of apx. 1 db.
Please Log In to view prices
Transformer - FenderĀ®, Power, for '59 Bassman Reissue
Fender® Original '59 Bassman Reissue Power Transformer. Equivalent to #036483.
Please Log In to view prices
Transformer - Marshall, Output, for JTM45
Special Order Item
Genuine Marshall™ output transformer for JTM45. Please Log In to view prices
Transformer - Marshall, Output, 50 W, for JCM 900
Special Order Item
Genuine Marshall™ output transformer for JCM900 and JCM2000. Please Log In to view prices
Transformer - Hammond, Power, 115V, 34V/50mA, 1.2VA, 161E24
Special Order Item
- Vertical mount, split bobbin design.
- Non-concentric wound.
- Low primary to secondary coupling - no electrostatic shield required.
- High insulation - Hipot of 2,000V RMS.
- Class B insulation - 130 degrees C.
- CSA certified (File # LR3902) and UL recognized (File #E207860).
Please Log In to view prices
Transformer - Hammond, Power, Low Voltage PC Mount Dual Primary
Special Order Item
- Operate on 50/60 Hz current
- Low profile, split bobbin design.
- Dual winding secondaries, non-concentrically wound
- Units are designed so that all windings must be used
- Low primary to secondary coupling - no electrostatic shield required.
- Universal dual primary 115/230V
- High insulation - Hipot of 2,500V RMS.
- Class B insulation - 130 degrees C.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 9 VCT
Special Order Item
Open style, chassis mount transformers with a 115V 60Hz primary and a 9V center tapped secondary. Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 24 V no tap
Special Order Item
Open style, chassis mount transformers with a 117V 50/60Hz primary and a 24V secondary. Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 25 V no tap
Special Order Item
Open style, chassis mount transformers with a 117V 50/60Hz primary and a 25V secondary. Please Log In to view prices
Transformer - Hammond, Low Voltage, Single Primary, 10V 5A
Current: 5 A
VA Rating: 50
Features:
Special Order Item
Secondary VAC: 10V C.T.Current: 5 A
VA Rating: 50
Features:
- Single Primary 115VAC
- Operates on 50/60 Hz.
- Combination solder or quick connect terminals.
- Split bobbin construction eliminates the need for an electrostatic shield.
- Hi-pot tested to 2 KV RMS.
- Economical open style, channel frame - chassis mount design
- UL recognized & CSA certified.
Please Log In to view prices
Transformer - Hammond, Low Voltage, Dual Primary, 12.6V 4A
Current: 4 A
VA Rating: 50.4
Features:
Special Order Item
Secondary VAC: 12.6V C.T.Current: 4 A
VA Rating: 50.4
Features:
- Dual Primary 115/230VAC
- Operates on 50/60 Hz.
- Combination solder or quick connect terminals.
- Split bobbin construction eliminates the need for an electrostatic shield.
- Hi-pot tested to 2 KV RMS.
- Economical open style, channel frame - chassis mount design
- UL recognized & CSA certified.
Please Log In to view prices