Transformers & Chokes

Transformer - Hammond, Filament High Current, 115V, 60V/5A, 300VA
Low Voltage, Filament High Current, Chassis Mount. 115 V primary.
Please Log In to view prices
P-T166-11 Transformer - Hammond, Low Voltage / Filament, Open, 11 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and an 11V center tapped secondary.
Please Log In to view prices
P-T166-12-NOTAP Transformer - Hammond, Low Voltage / Filament, Open, 12 V no tap
Special Order Item
Open style, chassis mount transformers with a 117V 50/60Hz primary and a 12V secondary.
Please Log In to view prices
P-T166-20 Transformer - Hammond, Low Voltage / Filament, Open, 20 VCT
Special Order Item
Open style, chassis mount transformers with a 115V 60Hz primary and a 20V center tapped secondary.
Please Log In to view prices
P-T166-44 Transformer - Hammond, Low Voltage / Filament, Open, 44 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 44V center tapped secondary.
Please Log In to view prices
P-T166-7 Transformer - Hammond, Low Voltage / Filament, Open, 7 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 7V or 7.5V secondary.
Please Log In to view prices
P-T166F120 Transformer - Hammond, Low Voltage / Filament, Open, 120 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 120V center tapped secondary.
Please Log In to view prices
P-T166G100 Transformer - Hammond, Low Voltage / Filament, Open, 100 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 100V center tapped secondary.
Please Log In to view prices
P-T166G60 Transformer - Hammond, Low Voltage / Filament, Open, 60 VCT
  • Open style, chassis mount transformers with a 115V 60Hz primary and a 60V center tapped secondary.
Please Log In to view prices
P-T166G80 Transformer - Hammond, Low Voltage / Filament, Open, 80 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and an 80V center tapped secondary.
Please Log In to view prices
P-T166K35 Transformer - Hammond, Low Voltage / Filament, Open, 35 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 35V center tapped secondary.
Please Log In to view prices
P-T166L22 Transformer - Hammond, Low Voltage / Filament, Open, 22 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 22V center tapped secondary.
Please Log In to view prices
P-T166L42 Transformer - Hammond, Low Voltage / Filament, Open, 42 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 42V center tapped secondary.
Please Log In to view prices
P-T166M48 Transformer - Hammond, Low Voltage / Filament, Open, 48 VCT
Open style, chassis mount transformers with a 117V 50/60Hz primary and a 48V center tapped secondary.
Please Log In to view prices
P-T166M72 Transformer - Hammond, Low Voltage / Filament, Open, 72 VCT
Open style, chassis mount transformers with a 117V 50/60Hz primary and a 72V center tapped secondary.
Please Log In to view prices
P-T167G120 Transformer - Hammond, Low Voltage / Filament, Enclosed, 120 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 120 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Enclosed, 36 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 36 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Enclosed, 50 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 50 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Enclosed, 60 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 60 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Enclosed, 10 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 10 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Please Log In to view prices
P-T167X-12D6 Transformer - Hammond, Low Voltage / Filament, Enclosed, 12.6 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 12 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Enclosed, 25 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 25 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Please Log In to view prices
Transformer - Hammond, Step-Up, 500VA
Capacity: 500VA Features:
  • Single winding does not provide isolation, for use where equipment is already isolated and only voltage change is required.
  • World wide applications, 50 or 60 Hz.
Please Log In to view prices
P-T185F24 Transformer - Hammond, Global Use, Dual Primary 115/230 VAC
  • Dual primary 115/230 VAC
  • 50/60 Hz. operation
  • Dual secondaries for series or parallel connections
  • 4,000 V RMS Hipot test
  • Class F insulation (155 degrees, C)
  • Chassis mount
  • Dual bobbin construction
  • Dual use terminals
  • C UL US recognized (E207860)
  • TUV Type Approved
  • CE certified to IEC 950 (Approved to EN 60-742 Safety Isolating Transformers)
Please Log In to view prices