Transformers & Chokes

Choke - Hammond, replacement for Vox TB35C2
16H @ 40 mA guitar amplifier replacement for Vox TB35C2 Tony Bruno. Physically, parts were designed to look similar to original factory units (where possible). Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Please Log In to view prices
Transformer - Hammond, Direct Box Transformer
Studio Grade Impedance Matching, 1140 Series. ​Designed with Nickel alloy cores for high performance and Wide Bandwidth. Frequency Response: 20 Hz – 20 kHz ±0.35 dB, (ref. @ 1 kHz). Low distortion at levels up to +27 dBu @ 20 Hz. Excellent Shielding – Mu Metal enclosures
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 18 VCT
  • Open style, chassis mount transformers with a 115V 60Hz or 50/60Hz primary and an 18V center tapped secondary.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 28 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 28V center tapped secondary.
Please Log In to view prices
Transformer - Hammond, Guitar Amplifier, replacement for Fender, 240 V
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • See P-T290-FENDER-120 for 120 V transformers, P-T290-Fender-120-UP for upgraded 120 V transformers

Warning: Not all amplifier models of the same name use the same transformer model.
Please Log In to view prices
Transformer - Fender®, Output, 50 W, 2 Ω
Fender® Original '59 Bassman Reissue output transformer. Equivalent to #036485.
Please Log In to view prices
Transformer - Fender®, Power, for '65 Twin Reverb Reissue
Made precisely to the original Fender® specifications. Drop-in replacement for '65 Twin Reverb Reissue. Made in the USA. 120V Primary.
Please Log In to view prices
Transformer - Hammond, Line Input Transformers
Studio Grade Impedance Matching, 1140 Series. ​Designed with Nickel alloy cores for high performance and Wide Bandwidth. Frequency Response: 20 Hz – 20 kHz ±0.35 dB, (ref. @ 1 kHz). Low distortion at levels up to +27 dBu @ 20 Hz. Excellent Shielding – Mu Metal enclosures
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 6V / 12V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 12 V series, 6 V parallel secondary.mary, 50/60 Hz. operation.
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 9V / 18V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 18 V series, 9 V parallel secondary.
Please Log In to view prices
Transformer - Hammond, Studio Grade Impedance Matching, 140 Series
Studio grade frequency response: 20 Hz. - 20 Khz. (+/- 1 db, ref. @ 1 Khz.) minimum. Excellent frequency response utilizing a 80% nickel core providing high permeability combined with low losses. Designed for maximum bandwidth, lowest distortion at +10 dbm power level or less. Plated steel cans, adjustable height case bracket.
Please Log In to view prices
Transformer - Hammond, 145 Series, Audio Chassis Mount
Features:
  • Small, economical, open, two hole horizontal bracket mount.
  • Insulated, color coded flexible leads, 4" long minimum
  • Frequency response 150 Hz. to 15 Khz. (+/- 1 db, reference 1000 Hz.)
  • When operating at impedances below nominal, power capability and the frequency spectrum are proportionately lower, conversely, at higher impedances power capability and frequency spectrum will be proportionately higher.
Please Log In to view prices
Transformer - Hammond, 146 Series, Audio Chassis Mount
Special Order Item
Features:
  • Small, economical, open, two hole horizontal bracket mount.
  • Insulated, color coded flexible leads, 3" long minimum
  • Frequency response 150 Hz. to 15 Khz. (+/- 1 db, reference 1000 Hz.)
  • When operating at impedances below nominal, power capability and the frequency spectrum are proportionately lower, conversely, at higher impedances power capability and frequency spectrum will be proportionately higher.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 16 VCT
Special Order Item
  • Open style, chassis mount transformers with a 115V 60Hz primary and a 16V center tapped secondary.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 25 VCT
Open style, chassis mount transformers with a 115V 60Hz or 117 50/60Hz primary and a 25V or 25.2V center tapped secondary.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Enclosed, 6.3 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 6.3 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Please Log In to view prices
Transformer - Hammond, Isolation, 100VA
Capacity: 100 VA
Features:
  • Primary 115VAC, 60 Hz.
  • Secondary taps @ 90, 100, 110, 115, 120 & 130VAC
  • Electrostatic shield between primary & secondary
  • Connection by flexible leads, 8" minimum length
  • Perfect for critical line voltage needs (examples: older "classic" tube equipment or Japanese 100V equipment).
  • CSA certified (# LR3902)
  • Remember - These units do NOT convert line frequency
Please Log In to view prices
Transformer - Hammond, Isolation / plug & receptacle
  • Primary 115VAC, 50 / 60 Hz., Secondary 115VAC
  • Provides complete circuit isolation.
  • Electrostatic shield between primary & secondary to greatly attenuate surges and noise.
  • Hi-pot tested to 2 KV RMS.
  • Circuit breaker in primary.
  • Standard 3-wire, grounded plug & receptacle.
  • Input (primary) connected to 5 foot long cord & standard North American plug (NEMA 5-15P).
  • Output (secondary) connected to 1 foot long "pig tail" cord, 3-wire, standard North American grounded receptacle (NEMA 5-15R).
  • North American Mark of Safety - C UL & UL listed (File #E211544)
  • Indoor use only
  • Remember - These units do NOT convert line frequency
Please Log In to view prices
Transformer - Hammond, Output, replacement for Orange Rocker 30
Hammond output transformer - replacement for Orange Rocker 30 Specifications: Part No. Pri Ohms Sec Ohms Amplifier Type Watts Bobbin/Paper Winding Equivalent To P-T1750ORF 6,000 C.T. 8, 16 Push-Pull 35 W Bobbin OT199SL
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 110V / 220V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 220 V series, 110 V parallel secondary.
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 117V / 234V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 234 V series, 117 V parallel secondary.
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 18V / 36V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 36 V series, 18 V parallel secondary.
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 22V / 44V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 44 V series, 22 V parallel secondary.
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 240V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 240V secondary.
Please Log In to view prices