Transformer - Hammond, Toroidal Power, 240V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 240V secondary.
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 9V / 18V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 18 V series, 9 V parallel secondary.
Please Log In to view prices
Transformer - Hammond, Studio Grade Impedance Matching, 140 Series
Studio grade frequency response: 20 Hz. - 20 Khz. (+/- 1 db, ref. @ 1 Khz.) minimum. Excellent frequency response utilizing a 80% nickel core providing high permeability combined with low losses. Designed for maximum bandwidth, lowest distortion at +10 dbm power level or less. Plated steel cans, adjustable height case bracket.
Please Log In to view prices
Transformer - Hammond, 145 Series, Audio Chassis Mount
Features:
  • Small, economical, open, two hole horizontal bracket mount.
  • Insulated, color coded flexible leads, 4" long minimum
  • Frequency response 150 Hz. to 15 Khz. (+/- 1 db, reference 1000 Hz.)
  • When operating at impedances below nominal, power capability and the frequency spectrum are proportionately lower, conversely, at higher impedances power capability and frequency spectrum will be proportionately higher.
Please Log In to view prices
Transformer - Hammond, 146 Series, Audio Chassis Mount
Special Order Item
Features:
  • Small, economical, open, two hole horizontal bracket mount.
  • Insulated, color coded flexible leads, 3" long minimum
  • Frequency response 150 Hz. to 15 Khz. (+/- 1 db, reference 1000 Hz.)
  • When operating at impedances below nominal, power capability and the frequency spectrum are proportionately lower, conversely, at higher impedances power capability and frequency spectrum will be proportionately higher.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 16 VCT
Special Order Item
  • Open style, chassis mount transformers with a 115V 60Hz primary and a 16V center tapped secondary.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 18 VCT
  • Open style, chassis mount transformers with a 115V 60Hz or 50/60Hz primary and an 18V center tapped secondary.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 25 VCT
Open style, chassis mount transformers with a 115V 60Hz or 117 50/60Hz primary and a 25V or 25.2V center tapped secondary.
Please Log In to view prices
Transformer - Hammond, Isolation, 100VA
Capacity: 100 VA
Features:
  • Primary 115VAC, 60 Hz.
  • Secondary taps @ 90, 100, 110, 115, 120 & 130VAC
  • Electrostatic shield between primary & secondary
  • Connection by flexible leads, 8" minimum length
  • Perfect for critical line voltage needs (examples: older "classic" tube equipment or Japanese 100V equipment).
  • CSA certified (# LR3902)
  • Remember - These units do NOT convert line frequency
Please Log In to view prices
Transformer - Hammond, Isolation / plug & receptacle
  • Primary 115VAC, 50 / 60 Hz., Secondary 115VAC
  • Provides complete circuit isolation.
  • Electrostatic shield between primary & secondary to greatly attenuate surges and noise.
  • Hi-pot tested to 2 KV RMS.
  • Circuit breaker in primary.
  • Standard 3-wire, grounded plug & receptacle.
  • Input (primary) connected to 5 foot long cord & standard North American plug (NEMA 5-15P).
  • Output (secondary) connected to 1 foot long "pig tail" cord, 3-wire, standard North American grounded receptacle (NEMA 5-15R).
  • North American Mark of Safety - C UL & UL listed (File #E211544)
  • Indoor use only
  • Remember - These units do NOT convert line frequency
Please Log In to view prices
Transformer - Hammond, Low Voltage, Single Primary, 120VCT
Special Order Item
  • Single Primary 115VAC
  • Operates on 50/60 Hz.
  • Combination solder or quick connect terminals.
  • Split bobbin construction eliminates the need for an electrostatic shield.
  • Hi-pot tested to 2 KV RMS.
  • Economical open style, channel frame - chassis mount design
  • UL recognized & CSA certified.
Please Log In to view prices
Choke - Hammond, Replacement for Vox AC30 reissue
Replacement for Vox AC30 reissue


Inductance ± 15%
5 H


D.C. Current
150 mA


Features:
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Inductances measured at rated D.C. current.
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • Units are vacuum impregnated with polyurethane varnish for quiet and long life operation.
Please Log In to view prices
Choke - Hammond, replacement for Vox TB35C2
16H @ 40 mA guitar amplifier replacement for Vox TB35C2 Tony Bruno. Physically, parts were designed to look similar to original factory units (where possible). Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 110V / 220V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 220 V series, 110 V parallel secondary.
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 24V / 48V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 48 V series, 24 V parallel secondary.
Please Log In to view prices
Transformer - Hammond, 144 Series, Audio Chassis Mount
Special Order Item
Features:
  • Small, economical, open, two hole horizontal bracket mount.
  • Insulated, color coded flexible leads, 4" long minimum
  • Frequency response 150 Hz. to 15 Khz. (+/- 1 db, reference 1000 Hz.)
  • When operating at impedances below nominal, power capability and the frequency spectrum are proportionately lower, conversely, at higher impedances power capability and frequency spectrum will be proportionately higher.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 24 VCT
Open style, chassis mount transformers with a 115V 60Hz or 117 50/60Hz primary and a 24V center tapped secondary.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 30 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 30 C.T.
  • Center tapped secondary.
  • Open style, channel bracket, two hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C).
  • Hi-Pot test of 2,000 V RMS.
  • UL listed (# E50394) & CSA certified (# LR3902).
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 36 VCT
  • Open style, chassis mount transformers with a 115V 60Hz or 117V 50/60Hz primary and a 36V center tapped secondary.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 33 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 33V center tapped secondary.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Enclosed, 6.3 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 6.3 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Please Log In to view prices
Transformer - Hammond, Isolation, 115V
  • Primary 115VAC, 60 Hz.
  • Secondary 115VAC
  • Electrostatic shield between primary & secondary
  • Connection by flexible leads, 8" minimum length
  • Perfect for circuit isolation or "Classic" bias power supply
  • CSA certified (209651)
  • Remember - These units do NOT convert line frequency
Please Log In to view prices
Transformer - Hammond, Power, Low voltage, 16V/3A
Specifications:
  • Size: 48 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 16V @ 3 A
  • Secondary VAC RMS Parallel: 8V @ 6 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra pr
Please Log In to view prices
Transformer - Hammond, Guitar Amplifier, replacement for Ampeg
  • Replacement for Ampeg amplifiers
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".



Part No.
Primary
Ampeg Model Names
Ampeg Part No
Bobbin/Paper Wound


VAC
Hz.




P-T291GX
120 V
60 Hz.
B25
12XA
Bobbin


P-T290CAZ
117 V
60 Hz.
Gemini VI 25W
PT 113
Bobbin


P-T290ETX
120 V
60 Hz.
Super Echo Twin
PT 109
Bobbin


P-T291HX
110 / 115 / 230 V
50 / 60 Hz.
V50H
94-270-030
Bobbin
Please Log In to view prices