Transformers & Chokes

Transformer - One Electron, Output, 4800 Ω to 16/8/4 Ω
The UBT-2 from One Electron is the same size and power (15 watts) as the UBT-1, but has a higher primary impedance suitable for single tubes running at B+ voltages of 400 to 500 volts, such as: 50, WE 300B,etc.
Please Log In to view prices
Transformer - Fender, Power, for Deluxe Reverb 120V
Genuine Fender power transformer designed for use in the ‘65 Deluxe Reverb as well as the ‘68 Deluxe. Made to original fender specifications. 120V Primary
Please Log In to view prices
Transformer - Hammond, Output, Single-Ended, 30 W
  • Over designed for single ended tube output circuits (triode, tetrode or pentode tubes).
  • Enclosed (shielded), 4 slot, above chassis Type 'X' mounting.
  • Frequency response at least 20 Hz. to 20 Khz. at full rated power (± 1 db max. ref.
Please Log In to view prices
Choke - Hammond, Replacement for Vox AC30 vintage
Replacement for Vox AC30 vintage


Inductance ± 15%
30 H


D.C. Current
100 mA


Features:
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Inductances measured at rated D.C. current.
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • Units are vacuum impregnated with polyurethane varnish for quiet and long life operation.
Please Log In to view prices
Transformer - One Electron, Output, 3000 Ω to 16/8/4 Ω
The UBT-3 from One Electron is the same size and power (15 watts) as the UBT-1, but has a primary impedance suitable for single or paralleled tubes running at B+ voltages of 300 to 400 volts, such as: 2A3, WE 300B, 50, etc.
Please Log In to view prices
Transformer - Hammond, Output, 8 W, 10k Primary
Specifications Audio Watts: 8 watts Primary Impendance (Ohms): 10K center-tapped Secondary Impendance (Ohms): 2/4/8 Mounting centers: 2-3/8u-bracket Weight: 1.0 lbs. Cat. No. Dimensions (Inches) A B C D G Mtg. Hole 125H 2.81 1.4 1.7 2.36 0.187
Please Log In to view prices
Transformer - Hammond, Isolation / plug & receptacle
  • Primary 115VAC, 50 / 60 Hz., Secondary 115VAC
  • Provides complete circuit isolation.
  • Electrostatic shield between primary & secondary to greatly attenuate surges and noise.
  • Hi-pot tested to 2 KV RMS.
  • Circuit breaker in primary.
  • Standard 3-wire, grounded plug & receptacle.
  • Input (primary) connected to 5 foot long cord & standard North American plug (NEMA 5-15P).
  • Output (secondary) connected to 1 foot long "pig tail" cord, 3-wire, standard North American grounded receptacle (NEMA 5-15R).
  • North American Mark of Safety - C UL & UL listed (File #E211544)
  • Indoor use only
  • Remember - These units do NOT convert line frequency
Please Log In to view prices
Transformer - Hammond, Power, 250-0-250 V, 100 mA
Primary 115 VAC 60 Hz.
Secondary DC current measured with cap. input filter, full wave (two diode) C.T., rectifier circuit.
Enclosed, 4 hole chassis mount.
Minimum 6 long leads.
2" X 2" vertical mounting centers.
Class A insulation (105 degrees C).
Hi-Pot test of 2000 V RMS.
Conservative designs - CSA certified (# LR3902).
3.2lbs
Secondary: 250-0-250 V100 mA
Filament winding 1: 5 V2 A
Filament winding 2: 6.3 V3 A
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 12V / 24V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 24 V series, 12 V parallel secondary.
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 110V / 220V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 220 V series, 110 V parallel secondary.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 24 VCT
Open style, chassis mount transformers with a 115V 60Hz or 117 50/60Hz primary and a 24V center tapped secondary.
Please Log In to view prices
Transformer - Fender®, Output, 50 W, 2 Ω
Fender® Original '59 Bassman Reissue output transformer. Equivalent to #036485.
Please Log In to view prices
Transformer - Isolation, 35 VA, 115V, 300 mA, 1 x 115V
35VA chassis mount Power Transformer for isolating equipment from direct connection to the power line. It is constructed with non-concentrically wound coils. The primary and secondary are wound on separate arbors, then assembled on a laminate core side-by-side separated by insulation. This prevents electrical connection under normal or overload conditions between the primary and secondary windings. These units are designed with 1500V isolation between winding to winding and between winding and core. Materials and construction are rated for Class B insulation system.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 18 VCT
  • Open style, chassis mount transformers with a 115V 60Hz or 50/60Hz primary and an 18V center tapped secondary.
Please Log In to view prices
Transformer - Lehle, Audio, Line-Bridging, Unbalanced to Balanced
The LEHLE TRANSFORMER MZ is the ideal component to avoid hum loops without degrading the sound. It achieves this through galvanic isolation of low to mid impedance audio signal sources. It can be used as an input or output transformer, for balanced or unbalanced signals.
Please Log In to view prices
Transformer - Hammond, 145 Series, Audio Chassis Mount
Features:
  • Small, economical, open, two hole horizontal bracket mount.
  • Insulated, color coded flexible leads, 4" long minimum
  • Frequency response 150 Hz. to 15 Khz. (+/- 1 db, reference 1000 Hz.)
  • When operating at impedances below nominal, power capability and the frequency spectrum are proportionately lower, conversely, at higher impedances power capability and frequency spectrum will be proportionately higher.
Please Log In to view prices
Choke - 0.17 - 250, Heavy Duty Hash Choke
Molded powdered iron core.
1-1/4 long axial leads.
High inductance & high current.
L measured at 1 Khz. Inductance: 250 µH20% tolerance
DC resistance ohms: .17
Self Resonant Frequency (MHz): 1.5
Maximum DC current amps: 2.5
Coil diameter (in): .43
Core Length (in): 1.25
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 36 VCT
  • Open style, chassis mount transformers with a 115V 60Hz or 117V 50/60Hz primary and a 36V center tapped secondary.
Please Log In to view prices
Transformer - Lehle, Audio, Line Isolation, High Impedance
The Lehle Transformer HZ is the ideal component to avoid hum loops or to balance and unbalance signals without degrading the sound of high impedance signal sources.
Please Log In to view prices
Transformer - Hammond, Output, replacement for Vox
  • Replacements for Vox Amps
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Please Log In to view prices
Transformer - Marshall, Output, 50 W, for JCM 900
Genuine Marshall™ output transformer for JCM900 and JCM2000.
Please Log In to view prices
Transformer - Marshall, Output, 30 W, for JTM30
Genuine Marshall™ 30 watt output transfomer for JTM30.
Please Log In to view prices
Transformer - One Electron, Output, 1600 Ω to 16/8/4 Ω
The UBT-1 from One Electron is a low-impedance single-ended output transformer intended for parallel combinations of tubes running a B+ voltages of 250 to 325 volts, such as: two or three EL34s (triode connected), three 2A3s, two 300Bs, two 6AS7s, etc., as well as single sweep tubes run in 'enhanced-triode' mode, resulting in 10 to 15 watts of output power.
Please Log In to view prices
Transformer - Hammond, Power, 350-0-350V, 70-90 mA
Custom manufactured to replace most 6 and 7 tube sets of the early 1930s. Supplied with vertical mounting shells. Provides a seperate filament winding for audio output stages. Specifications Rating: 350-0-350 V, 70 or 90 mA (if 5 V winding is used with 2 A rectifier) Windings: 5 V, 3 A; 2.5 V, 7.5 A; 2.5 VCT, 3.5 A Mounting Centers:2 x 2.625" Weight: 4.2 lbs. Overall Height: 3.12"
Please Log In to view prices