Transformers & Chokes
Transformer - Hammond, Plate & Filament or Bias, 6.3 V auxiliary
- Primary 115 VAC, 60 Hz.
- Designed for small power or bias supplies, test equipment, preamps etc.
- Models P-T261C6, P-T261E6, and P-T261G6 can also be used with full wave C.T. rectifiers.
- Economical , two hole, channel bracket, chassis mount.
- Minimum 5" long leads.
- Convenient 6.3 filament/auxiliary winding.
Please Log In to view prices
Transformer - Isolation, 50 VA, 115V, 435 mA, 2 x 115V
An Isolation Power Transformer for isolating equipment from direct connection to the power line. The transformer is constructed with non-concentrically wound coils. The primary and secondary are wound on separate arbors, then assembled on a laminate core side-by-side separated by insulation. This prevents electrical connection, under normal or overload conditions, between the primary and secondary windings.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 2.5 VCT
- Open style, chassis mount transformers with a 115V 60Hz primary and a 2.5V center tapped secondary.
Please Log In to view prices
Transformer - Output, 8 W, 4kΩ - 9kΩ impedance
Specifications Output 8 W Primary Impedance 4,000 to 9,000 Ω Mounting Centers 2.375" Weight 0.7 lbs
Please Log In to view prices
Transformer - Fender®, Power, Hot Rod Deluxe
Fender Original Hot Rod Deluxe Power Transformer. Equivalent to #036958.
Specifications
Primary
120 VAC @ 60 Hz (Black - White)
Secondary 1 (Red - Red)
495 VDC unloaded, 440 VDC @ 65.7 mA DC, 388 VDC @ 200 mA DC
Secondary 2 (Brown - Brown)
53.6 VAC @ 1.58 A AC
Secondary 3 (Green - Green)
6.6 VAC @ 3.75 A AC
Warning: Not all amplifier models of the same name use the same transformer model. Please make sure the amplifier transformer which you are replacing has a Fender number matching the equivalent Fender transformer number listed here.
Specifications
Primary
120 VAC @ 60 Hz (Black - White)
Secondary 1 (Red - Red)
495 VDC unloaded, 440 VDC @ 65.7 mA DC, 388 VDC @ 200 mA DC
Secondary 2 (Brown - Brown)
53.6 VAC @ 1.58 A AC
Secondary 3 (Green - Green)
6.6 VAC @ 3.75 A AC
Warning: Not all amplifier models of the same name use the same transformer model. Please make sure the amplifier transformer which you are replacing has a Fender number matching the equivalent Fender transformer number listed here.
Please Log In to view prices
Transformer - Hammond, Universal Push-Pull
- Designed for general purpose or replacement use in push-pull tube output circuits. (For single ended use, see our 125 SE series - optimized for single ended tube output circuits).
- Frequency response: 150 Hz. - 15 Khz (± 1db max. ref. 1 Khz).
- Open style with minimum 5" long primary leads, secondary solder lugs for convenient secondary connections.
- Tables provided with transformer listing 90 pre-calculated impedance ratios.
Please Log In to view prices
Transformer - Hammond, Guitar Amplifier, replacement for Fender, 120 V upgrade
Warning: Not all amplifier models of the same name use the same transformer model.
- Designed for drop in replacement of original units. Upgraded units with variable voltage.
- Physically, parts were designed to look similar to original factory units (where possible).
- Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
- See P-T290-FENDER-120 for 120 V basic transformers, P-T290-FENDER-240 for 240 V transformers
Warning: Not all amplifier models of the same name use the same transformer model.
Please Log In to view prices
Transformer - Audio Interstage, Coil Assembly for P-T156
Coil assembly for P-T156. Use your own iron to preserve mechanical fit. Coil window is 1/2 x ½".
Please Log In to view prices
Switch - Rotary Impedance Selector, for Hammond 1600A series
Includes: 3 pole, 3 position rotary switch (3P3T), 1/4" output jack and black chicken head knob. Hammond 1600A series transformers provide 'easy wire secondary' impedances of 4, 8, or 16 ohms. We now offer a selector switch, pre-wired and complete with 1/4" output jack. Follow simple instructions provided to wire transformer secondary to switch, mount switch and 1/4" jack in separate 3/8" diameter holes in chassis and you'll easily be able to select output impedance as necessary. (Not recommended for 1645A or 1650G)
(See P-H1600 for a selector switch to work with Hammond 1600 series transformers.)
(See P-H1600 for a selector switch to work with Hammond 1600 series transformers.)
Please Log In to view prices
Transformer - Fender®, Output, Hot Rod Deluxe and Blues Deluxe
Fender Original Hot Rod Deluxe and Blues Deluxe output transformer. 40 watts. Equivalent to #050438.
Please Log In to view prices
Filter Choke - Hammond, D.C. choke, Enclosed
- Enclosed, 4-hole mount chokes
- Tolerance of 15% on both inductance & resistance.
- Inductances measured at rated D.C. current.
- Minimum 8" long leads.
- Units will exhibit less inductance at slightly higher currents or more at lower currents.
- Perfect for high voltage power supply filtering, case matches power transformers & tube audio output transformers.
- Units are vacuum impregnated with polyurethane varnish for quiet and long life operation.
- For more sizes and voltages (open - bracket mount type) - see P-T154-P-T156-X
- Operating temperature range is -40C to 85C
Please Log In to view prices
Transformer - Hammond, Tube Output, Easy Wire Secondary
- Designed for push-pull tube output circuits.
- Enclosed (shielded), 4 slot, above chassis Type 'X' mounting.
- Frequency response 30 Hz. to 30 Khz. at full rated power (± 1 db max. - ref.
Please Log In to view prices
Transformer - Power, 117 V primary, 125 V @ 15 mA secondary
Specifications Primary 117 V, 50/60 Hz Secondary 125 V, 15 mA Filament Winding 12.6V, 0.3 A Mounting Centers 2" Mounting Type U-bracket Weight 0.7 lbs
Please Log In to view prices
Transformer - Hammond, Plate & Filament
- Universal primary with taps for 100, 120, 220 or 240 VAC, 50 / 60 Hz. (Except the 260A6 which is 117V, 50/60 Hz only)
- Designed for preamps, low power amps, general replacement, test equipment, etc.
- Economical, open frame, chassis mount - two hole (.187 dia. = G) channel bracket (figure #1) or four hole mounting (figure #2).
- Units include a Faraday shield between the primary and secondary windings. Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries.
- Minimum 5" long leads.
- For more selection check out our P-T300-X series of universal plate & filament transformers.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 12.6 VCT
- Open style, chassis mount transformers with a 115V 60Hz or 117 50/60Hz primary and a 12.6V center tapped secondary
Please Log In to view prices
Transformer - Fender® Replacement, Output, 50 W, 4 Ohm
Replacement for Bassman heads. Equivalent to #125A13A & #022871.
Please Log In to view prices
Transformer - Hammond, Line Output Transformers
Studio Grade Impedance Matching, 1140 Series. Designed with Nickel alloy cores for high performance and Wide Bandwidth. Frequency Response: 20 Hz – 20 kHz ±0.35 dB, (ref. @ 1 kHz). Low distortion at levels up to +27 dBu @ 20 Hz. Open Style
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 5 VCT
- Open style, chassis mount transformers with a 115V 60Hz primary and a 5V center tapped secondary.
Please Log In to view prices
Transformer - Hammond, Filament, Open, 6.3 VCT, 117V/100V 50/60Hz Primary
Open frame 6.3V center tapped filament transformer with a 117V 50/60Hz. primary featuring a 100V tap for Japan
- Open Style, Chassis mount
- 117 VAC, 50/60 Hz. with 100V Tap
- Secondary 6.3 C.T.
- Center tapped secondary
- Open style, channel bracket, two hole chassis mount
- Minimum 6" long leads
- Dual bobbin design - no electrostatic shield required
- Class B insulation (130 degrees, C)
- Hi-Pot test of 2,000 V RMS
- CSA certified
Please Log In to view prices
Transformer - Marshall Replacement, Output, 100 W
Great for upgrading later issue Marshall™ amps. Gives great classic sound.
Good replacement for JMP and JCM 800s. for EL34!
Good replacement for JMP and JCM 800s. for EL34!
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 110V / 220V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 220 V series, 110 V parallel secondary.
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 12V / 24V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 24 V series, 12 V parallel secondary.
Please Log In to view prices
Transformer - Fender®, Power, Blues Junior, 15 W
Fender Original Blues Junior Power Transformer. Equivalent to #049967.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 12 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 12V center tapped secondary.
Please Log In to view prices