Transformers & Chokes

Transformer - Power, 120V primary, 140/28/10.5 V secondary
  • Primary Voltage: 120 V
  • Secondary 1: 140 V @ 100 mA
  • Secondary 2: 28 V @ 20 mA
  • Secondary 3: 10.5 V @ 2 A

Primary voltage = black wires Secondary 1 = Red wires Secondary 2 = Yellow wires Secondary 3 = Green wires
Please Log In to view prices
Transformer - Hammond, Universal Push-Pull
  • Designed for general purpose or replacement use in push-pull tube output circuits. (For single ended use, see our 125 SE series - optimized for single ended tube output circuits).
  • Frequency response: 150 Hz. - 15 Khz (± 1db max. ref. 1 Khz).
  • Open style with minimum 5" long primary leads, secondary solder lugs for convenient secondary connections.
  • Tables provided with transformer listing 90 pre-calculated impedance ratios.
Please Log In to view prices
Transformer - Fender®, Output, Hot Rod Deluxe and Blues Deluxe
Fender Original Hot Rod Deluxe and Blues Deluxe output transformer. 40 watts. Equivalent to #050438.
Please Log In to view prices
Transformer - Isolation, 50 VA, 115V, 435 mA, 2 x 115V
An Isolation Power Transformer for isolating equipment from direct connection to the power line. The transformer is constructed with non-concentrically wound coils. The primary and secondary are wound on separate arbors, then assembled on a laminate core side-by-side separated by insulation. This prevents electrical connection, under normal or overload conditions, between the primary and secondary windings.
Please Log In to view prices
Transformer - Power, 117 V primary, 125 V @ 15 mA secondary
Specifications Primary 117 V, 50/60 Hz Secondary 125 V, 15 mA Filament Winding 12.6V, 0.3 A Mounting Centers 2" Mounting Type U-bracket Weight 0.7 lbs
Please Log In to view prices
Transformer - 42TM022, Audio & Signal, 1.5KΩ:600Ω, PC Mount
Small 42TM022 audio transformers with a 1.5KΩ:600Ω impedance. This transformer is a popular choice for octavia style builds as well as ring modulators. The leads are soft metal wire and can be adjusted to fit a variety of applications. RoHS compliant. Rated for 200mW.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 12.6 VCT
  • Open style, chassis mount transformers with a 115V 60Hz or 117 50/60Hz primary and a 12.6V center tapped secondary
Please Log In to view prices
Transformer - Hammond, Tube Output, Easy Wire Secondary
  • Designed for push-pull tube output circuits.
  • Enclosed (shielded), 4 slot, above chassis Type 'X' mounting.
  • Frequency response 30 Hz. to 30 Khz. at full rated power (± 1 db max. - ref.
Please Log In to view prices
Transformer - Marshall Replacement, Output, 100 W
Great for upgrading later issue Marshall™ amps. Gives great classic sound.
Good replacement for JMP and JCM 800s. for EL34!
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 110V / 220V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 220 V series, 110 V parallel secondary.
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 12V / 24V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 24 V series, 12 V parallel secondary.
Please Log In to view prices
Transformer - Marshall Replacement, Power for JTM45
Replacement power transformer for Marshall JTM45.
Please Log In to view prices
Transformer - Fender® Replacement, Output, 35 W
Replacement for Pro Reverb, Tremolux, Vibrolux, Bandmaster, and Vibroverb. Equivalent to #125A6A & #022848.
Please Log In to view prices
Transformer - Fender, Power, for Deluxe Reverb 120V
Genuine Fender power transformer designed for use in the ‘65 Deluxe Reverb as well as the ‘68 Deluxe. Made to original fender specifications. 120V Primary
Please Log In to view prices
Transformer - Hammond, Audio Interstage, 12 Watt
Developed in response to requests from the Collins Collectors Association"this is a matching audio transformer for older equipment with 600 ohm audio outputdriving modern speakers. Or for "classic" high impedance speakers used with newer equipmentsimply swap primary for secondary (ie...4 or 8 ohm input and 600 ohms out). Key Features Isolation unit: (i.e.
Please Log In to view prices
Transformer - Hammond, Line Output Transformers
Studio Grade Impedance Matching, 1140 Series. ​Designed with Nickel alloy cores for high performance and Wide Bandwidth. Frequency Response: 20 Hz – 20 kHz ±0.35 dB, (ref. @ 1 kHz). Low distortion at levels up to +27 dBu @ 20 Hz. Open Style
Please Log In to view prices
Choke - 0.17 - 250, Heavy Duty Hash Choke
Molded powdered iron core.
1-1/4 long axial leads.
High inductance & high current.
L measured at 1 Khz. Inductance: 250 µH20% tolerance
DC resistance ohms: .17
Self Resonant Frequency (MHz): 1.5
Maximum DC current amps: 2.5
Coil diameter (in): .43
Core Length (in): 1.25
Please Log In to view prices
Transformer - Hammond, Plate & Filament
  • Universal primary with taps for 100, 120, 220 or 240 VAC, 50 / 60 Hz. (Except the 260A6 which is 117V, 50/60 Hz only)
  • Designed for preamps, low power amps, general replacement, test equipment, etc.
  • Economical, open frame, chassis mount - two hole (.187 dia. = G) channel bracket (figure #1) or four hole mounting (figure #2).
  • Units include a Faraday shield between the primary and secondary windings. Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries.
  • Minimum 5" long leads.
  • For more selection check out our P-T300-X series of universal plate & filament transformers.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 12 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 12V center tapped secondary.
Please Log In to view prices
Transformer - Hammond, Guitar Amplifier, replacement for Fender, 240 V
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • See P-T290-FENDER-120 for 120 V transformers, P-T290-Fender-120-UP for upgraded 120 V transformers

Warning: Not all amplifier models of the same name use the same transformer model.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 5 VCT
  • Open style, chassis mount transformers with a 115V 60Hz primary and a 5V center tapped secondary.
Please Log In to view prices
Transformer - Fender®, Power, Blues Junior, 15 W
Fender Original Blues Junior Power Transformer. Equivalent to #049967.
Please Log In to view prices
Transformer - Hammond, Output, 8 W, 10k Primary
Specifications Audio Watts: 8 watts Primary Impendance (Ohms): 10K center-tapped Secondary Impendance (Ohms): 2/4/8 Mounting centers: 2-3/8u-bracket Weight: 1.0 lbs. Cat. No. Dimensions (Inches) A B C D G Mtg. Hole 125H 2.81 1.4 1.7 2.36 0.187
Please Log In to view prices
Transformer - Hammond, Power, 250-0-250 V, 100 mA
Primary 115 VAC 60 Hz.
Secondary DC current measured with cap. input filter, full wave (two diode) C.T., rectifier circuit.
Enclosed, 4 hole chassis mount.
Minimum 6 long leads.
2" X 2" vertical mounting centers.
Class A insulation (105 degrees C).
Hi-Pot test of 2000 V RMS.
Conservative designs - CSA certified (# LR3902).
3.2lbs
Secondary: 250-0-250 V100 mA
Filament winding 1: 5 V2 A
Filament winding 2: 6.3 V3 A
Please Log In to view prices