Transformers & Chokes

Power Transformer - Hammond, 115V, 28VCT
Special Order Item
  • Both series operate on 50/60 Hz current
  • Low profile, split bobbin design.
  • Dual winding secondaries, non-concentrically wound
  • Units are designed so that all windings must be used
  • Low primary to secondary coupling - no electrostatic shield required.
  • High insulation - Hipot of 2,500V RMS.
  • Class B insulation - 130 degrees C.
  • c UL us recognized
Please Log In to view prices
Transformer - Fender, Power, for Deluxe Reverb 120V
Genuine Fender power transformer designed for use in the ‘65 Deluxe Reverb as well as the ‘68 Deluxe. Made to original fender specifications. 120V Primary
Please Log In to view prices
Transformer - Fender®, Power, Blues Junior, 15 W
Fender Original Blues Junior Power Transformer. Equivalent to #049967.
Please Log In to view prices
Transformer - Fender®, Power, Hot Rod Deluxe
Fender Original Hot Rod Deluxe Power Transformer. Equivalent to #036958.



Specifications



Primary
120 VAC @ 60 Hz (Black - White)


Secondary 1 (Red - Red)
495 VDC unloaded, 440 VDC @ 65.7 mA DC, 388 VDC @ 200 mA DC


Secondary 2 (Brown - Brown)
53.6 VAC @ 1.58 A AC


Secondary 3 (Green - Green)
6.6 VAC @ 3.75 A AC


Warning: Not all amplifier models of the same name use the same transformer model. Please make sure the amplifier transformer which you are replacing has a Fender number matching the equivalent Fender transformer number listed here.
Please Log In to view prices
Transformer - Fender®, Power, Hot Rod Deville
Fender Original Hot Rod DeVille Power Transformer. Equivalent to #041752.
Please Log In to view prices
Transformer - Hammond, Filament High Current, 115V, 60V/5A, 300VA
Low Voltage, Filament High Current, Chassis Mount. 115 V primary.
Please Log In to view prices
Transformer - Hammond, Global Use, Dual Primary 115/230 VAC
  • Dual primary 115/230 VAC
  • 50/60 Hz. operation
  • Dual secondaries for series or parallel connections
  • 4,000 V RMS Hipot test
  • Class F insulation (155 degrees, C)
  • Chassis mount
  • Dual bobbin construction
  • Dual use terminals
  • C UL US recognized (E207860)
  • TUV Type Approved
  • CE certified to IEC 950 (Approved to EN 60-742 Safety Isolating Transformers)
Please Log In to view prices
Transformer - Hammond, Guitar Amplifier, replacement for Ampeg
  • Replacement for Ampeg amplifiers
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".



Part No.
Primary
Ampeg Model Names
Ampeg Part No
Bobbin/Paper Wound


VAC
Hz.




P-T291GX
120 V
60 Hz.
B25
12XA
Bobbin


P-T290CAZ
117 V
60 Hz.
Gemini VI 25W
PT 113
Bobbin


P-T290ETX
120 V
60 Hz.
Super Echo Twin
PT 109
Bobbin


P-T291HX
110 / 115 / 230 V
50 / 60 Hz.
V50H
94-270-030
Bobbin
Please Log In to view prices
Transformer - Hammond, Guitar Amplifier, replacement for Fender, 120 V
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • See P-T290-FENDER-120-UP for upgraded 120 V transformers, P-T290-FENDER-240 for 240 V transformers

Warning: Not all amplifier models of the same name use the same transformer model.
Please Log In to view prices
Transformer - Hammond, Guitar Amplifier, replacement for Fender, 120 V upgrade
  • Designed for drop in replacement of original units. Upgraded units with variable voltage.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • See P-T290-FENDER-120 for 120 V basic transformers, P-T290-FENDER-240 for 240 V transformers

Warning: Not all amplifier models of the same name use the same transformer model.
Please Log In to view prices
Transformer - Hammond, Guitar Amplifier, replacement for Fender, 240 V
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • See P-T290-FENDER-120 for 120 V transformers, P-T290-Fender-120-UP for upgraded 120 V transformers

Warning: Not all amplifier models of the same name use the same transformer model.
Please Log In to view prices
Transformer - Hammond, Guitar Amplifier, replacement for Marshall
  • Replacements for Marshall amps
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Please Log In to view prices
Transformer - Hammond, Guitar Amplifier, replacement for Vox
  • Replacement for Vox amplifiers
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Please Log In to view prices
Transformer - Hammond, Guitar Amplifier, replacement for Yorkville / Traynor
  • Replacement for Yorkville/Traynor amplifiers
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".

Part No. Primary Secondary 1 Secondary 2 Secondary 3 Yorkville / Traynor Amp Yorkville / Traynor Part No VAC Hz. P-T290TRA 120 V 60 Hz. 320 V @ 600 mA 60 V @ 50 mA 6.3 V.C.T. @ 9 A 100 Watt Bass A-1380 P-T290TRB 120 V 60 Hz. 620 V @ 115 mA 6.3 V.C.T. @ 115 mA YBA2-B A-1314 P-T291JX 120 V 60 Hz. 320 V @ 500 mA 60 V @ 20 mA 6.65 V.C.T.
Please Log In to view prices
Transformer - Hammond, High Voltage Plate & Filament, Horizontal mount
  • Horizontal mount. For Vertical Mount, see P-T263-X
  • Primary 117 VAC, 50/60 Hz. - except as noted
  • Enclosed, 4 hole, chassis mount.
  • Minimum 6" long leads.
  • Units can be run full wave bridge or full wave C.T.
  • Class A insulation (105 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • Conservative designs - CSA certified (209651).
  • For Vertical Mount, see P-T263-X
Please Log In to view prices
Transformer - Hammond, High Voltage Plate & Filament, Vertical mount
  • Vertical Mount. For Horizontal Mount, see P-T263-Z
  • Primary 115 VAC, 60 Hz. - except as noted
  • Enclosed, 4 hole, chassis mount.
  • Minimum 6" long leads.
  • Units can be run full wave bridge or full wave C.T.
  • Class A insulation (105 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • Conservative designs - CSA certified (209651).
Please Log In to view prices
Transformer - Hammond, High Voltage Plate, 115 VAC, 50 / 60 Hz
  • Primary 115 VAC, 50 / 60 Hz.
  • At 2,000 VAC and above, secondary leads are through rubber bushings
  • Units can be run full wave bridge or full wave C.T.
  • V.A. is a C.C.S. rating
  • Current ratings are CCS (Continuous Commercial Service) & ICAS ratings (Intermittent Commercial or Amateur Service).
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Class A insulation (105 degrees C).
  • Hi-Pot test at a minimum of twice secondary voltage
  • Conservative designs - CSA certified (209651).
Please Log In to view prices
Transformer - Hammond, High Voltage Universal Plate & Filament, Horizontal mount
  • Primary: Universal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz.
    • NOTE: units are designed to operate with BOTH primary windings engaged.
    • See primary wiring information under resources.
  • Bias Tap: 50 VAC tap from high voltage secondary C.T.
Please Log In to view prices
Transformer - Hammond, High Voltage Universal Plate & Filament, Vertical mount
  • Primary: Universal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz.
    • NOTE: units are designed to operate with BOTH primary windings engaged.
    • See primary wiring information under resources.
  • Bias Tap: 50 VAC tap from high voltage secondary C.T. (except part number P-T379WX - uses a separate 60VAC 0.2 Amp winding).
  • Highpot tested: 2,000 VAC
  • Faraday Copper Primary Shield: Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries (shield is internally grounded to the end bell).
  • Windings: Concentric wound for low stray field and low noise.
  • Models: This series is an upgrade from our P-T263-X range of units PLUS 2 models designed specifically for 300B tubes (Part Number P-T300BX) and 2A3 tubes (Part Number P-T302AX).
  • Finish: Black powder paint to match our P-T1650X series of output transformers Units can be run full wave bridge or full wave C.T.
  • Conservative designs - CSA certified (209651).
Please Log In to view prices
Transformer - Hammond, Isolation / plug & receptacle
  • Primary 115VAC, 50 / 60 Hz., Secondary 115VAC
  • Provides complete circuit isolation.
  • Electrostatic shield between primary & secondary to greatly attenuate surges and noise.
  • Hi-pot tested to 2 KV RMS.
  • Circuit breaker in primary.
  • Standard 3-wire, grounded plug & receptacle.
  • Input (primary) connected to 5 foot long cord & standard North American plug (NEMA 5-15P).
  • Output (secondary) connected to 1 foot long "pig tail" cord, 3-wire, standard North American grounded receptacle (NEMA 5-15R).
  • North American Mark of Safety - C UL & UL listed (File #E211544)
  • Indoor use only
  • Remember - These units do NOT convert line frequency
Please Log In to view prices
Transformer - Hammond, Isolation, 100VA
Capacity: 100 VA
Features:
  • Primary 115VAC, 60 Hz.
  • Secondary taps @ 90, 100, 110, 115, 120 & 130VAC
  • Electrostatic shield between primary & secondary
  • Connection by flexible leads, 8" minimum length
  • Perfect for critical line voltage needs (examples: older "classic" tube equipment or Japanese 100V equipment).
  • CSA certified (# LR3902)
  • Remember - These units do NOT convert line frequency
Please Log In to view prices
Transformer - Hammond, Isolation, 115V
  • Primary 115VAC, 60 Hz.
  • Secondary 115VAC
  • Electrostatic shield between primary & secondary
  • Connection by flexible leads, 8" minimum length
  • Perfect for circuit isolation or "Classic" bias power supply
  • CSA certified (209651)
  • Remember - These units do NOT convert line frequency
Please Log In to view prices
Transformer - Hammond, Line European grounded adaptor plug
Special Order Item
European plug type Used in: Austria; Belgium; Finland; France; Germany; Middle East; Netherlands; Norway; Parts of Africa, Asia ,South America, China, Tahiti and Caribbean; Sweden Features:
  • For use with Hammond transformers
  • Heavy duty design with plastic shell & double wipe contacts.
  • Indoor use only.
  • Allows for ground connection between equipment and international power sources.
  • Adaptors do not affect voltages, they are a mechanical device only to match foreign "pin-outs" of receptacles and/or plugs.
Please Log In to view prices
Transformer - Hammond, Line Step Up Isolation, Toroidal, 500 VA
Capacity: 500 VA
Dimensions: 9" long by 6" wide by 4" height
Features:
  • Primary 120VAC, 50/60 Hz., Secondary 240VAC.
  • Provides circuit isolation.
  • Toroidal transformer for high isolation, low noise, light weight cool operation and low profile.
  • 50 or 60 Hz.
Please Log In to view prices