Transformers & Chokes

Transformer - Hammond, Guitar Amplifier, replacement for Fender, 120 V
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • See P-T290-FENDER-120-UP for upgraded 120 V transformers, P-T290-FENDER-240 for 240 V transformers

Warning: Not all amplifier models of the same name use the same transformer model.
Please Log In to view prices
Transformer - Hammond, High Voltage Plate & Filament, Vertical mount
  • Vertical Mount. For Horizontal Mount, see P-T263-Z
  • Primary 115 VAC, 60 Hz. - except as noted
  • Enclosed, 4 hole, chassis mount.
  • Minimum 6" long leads.
  • Units can be run full wave bridge or full wave C.T.
  • Class A insulation (105 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • Conservative designs - CSA certified (209651).
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 6.3 VCT
  • Open style, chassis mount transformers with a 115V 60Hz or 117 50/60Hz primary and a 6.3V center tapped secondary.
Please Log In to view prices
Transformer - Hammond, Plate & Filament or Bias, 6.3 V auxiliary
  • Primary 115 VAC, 60 Hz.
  • Designed for small power or bias supplies, test equipment, preamps etc.
  • Models P-T261C6, P-T261E6, and P-T261G6 can also be used with full wave C.T. rectifiers.
  • Economical , two hole, channel bracket, chassis mount.
  • Minimum 5" long leads.
  • Convenient 6.3 filament/auxiliary winding.
Please Log In to view prices
Transformer - Fender® Replacement, Power, 325-0-325 V, 200 mA
Replacement for Fender Super Reverb, Pro Reverb, Bandmaster, and Tweed Bassman. Includes rectifier tap.
Equivalent to #125P5D & #022798.
Please Log In to view prices
Transformer - Fender® Replacement, Power, 330-0-330 V, 120 mA
Replacement for Fender Deluxe, Deluxe Reverb. Equivalent to #125P23B. Note: Does not fit Reissue '65 Reverb.
Please Log In to view prices
Transformer - Isolation, 50 VA, 115V, 435 mA, 2 x 115V
An Isolation Power Transformer for isolating equipment from direct connection to the power line. The transformer is constructed with non-concentrically wound coils. The primary and secondary are wound on separate arbors, then assembled on a laminate core side-by-side separated by insulation. This prevents electrical connection, under normal or overload conditions, between the primary and secondary windings.
Please Log In to view prices
Transformer - Hammond, Guitar Amplifier, replacement for Marshall
  • Replacements for Marshall amps
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Please Log In to view prices
Transformer - Fender®, Power, Hot Rod Deluxe
Fender Original Hot Rod Deluxe Power Transformer. Equivalent to #036958.



Specifications



Primary
120 VAC @ 60 Hz (Black - White)


Secondary 1 (Red - Red)
495 VDC unloaded, 440 VDC @ 65.7 mA DC, 388 VDC @ 200 mA DC


Secondary 2 (Brown - Brown)
53.6 VAC @ 1.58 A AC


Secondary 3 (Green - Green)
6.6 VAC @ 3.75 A AC


Warning: Not all amplifier models of the same name use the same transformer model. Please make sure the amplifier transformer which you are replacing has a Fender number matching the equivalent Fender transformer number listed here.
Please Log In to view prices
Transformer - Fender® Replacement, Power, 325-0-325 V, 180 mA
Replacement for Fender Vibrolux and Tremolux Blackface AA763 (1963-1966).
Equivalent to #125P26A & # 036483. 35 Watts.
Please Log In to view prices
Transformer - Marshall Replacement, Power, 50 W
A good upgrade for later issue Marshall amplifiers. Good replacement for JMP and JCM 800s for EL34!
Please Log In to view prices
Transformer - Hammond, High Voltage Universal Plate & Filament, Vertical mount
  • Primary: Universal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz.
    • NOTE: units are designed to operate with BOTH primary windings engaged.
    • See primary wiring information under resources.
  • Bias Tap: 50 VAC tap from high voltage secondary C.T. (except part number P-T379WX - uses a separate 60VAC 0.2 Amp winding).
  • Highpot tested: 2,000 VAC
  • Faraday Copper Primary Shield: Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries (shield is internally grounded to the end bell).
  • Windings: Concentric wound for low stray field and low noise.
  • Models: This series is an upgrade from our P-T263-X range of units PLUS 2 models designed specifically for 300B tubes (Part Number P-T300BX) and 2A3 tubes (Part Number P-T302AX).
  • Finish: Black powder paint to match our P-T1650X series of output transformers Units can be run full wave bridge or full wave C.T.
  • Conservative designs - CSA certified (209651).
Please Log In to view prices
Transformer - Fender®, Power, Blues Junior, 15 W
Fender Original Blues Junior Power Transformer. Equivalent to #049967.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 5 VCT
  • Open style, chassis mount transformers with a 115V 60Hz primary and a 5V center tapped secondary.
Please Log In to view prices
Transformer - Hammond, Guitar Amplifier, replacement for Fender, 240 V
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • See P-T290-FENDER-120 for 120 V transformers, P-T290-Fender-120-UP for upgraded 120 V transformers

Warning: Not all amplifier models of the same name use the same transformer model.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 2.5 VCT
  • Open style, chassis mount transformers with a 115V 60Hz primary and a 2.5V center tapped secondary.
Please Log In to view prices
Transformer - Hammond, High Voltage Plate & Filament, Horizontal mount
  • Horizontal mount. For Vertical Mount, see P-T263-X
  • Primary 117 VAC, 50/60 Hz. - except as noted
  • Enclosed, 4 hole, chassis mount.
  • Minimum 6" long leads.
  • Units can be run full wave bridge or full wave C.T.
  • Class A insulation (105 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • Conservative designs - CSA certified (209651).
  • For Vertical Mount, see P-T263-X
Please Log In to view prices
Transformer - Hammond, Guitar Amplifier, replacement for Fender, 120 V upgrade
  • Designed for drop in replacement of original units. Upgraded units with variable voltage.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • See P-T290-FENDER-120 for 120 V basic transformers, P-T290-FENDER-240 for 240 V transformers

Warning: Not all amplifier models of the same name use the same transformer model.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 12 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 12V center tapped secondary.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 12.6 VCT
  • Open style, chassis mount transformers with a 115V 60Hz or 117 50/60Hz primary and a 12.6V center tapped secondary
Please Log In to view prices
Transformer - Hammond, Guitar Amplifier, replacement for Vox
  • Replacement for Vox amplifiers
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Please Log In to view prices
Transformer - Fender, Power, for Deluxe Reverb 120V
Genuine Fender power transformer designed for use in the ‘65 Deluxe Reverb as well as the ‘68 Deluxe. Made to original fender specifications. 120V Primary
Please Log In to view prices
Transformer - Hammond, Power, 250-0-250 V, 100 mA
Primary 115 VAC 60 Hz.
Secondary DC current measured with cap. input filter, full wave (two diode) C.T., rectifier circuit.
Enclosed, 4 hole chassis mount.
Minimum 6 long leads.
2" X 2" vertical mounting centers.
Class A insulation (105 degrees C).
Hi-Pot test of 2000 V RMS.
Conservative designs - CSA certified (# LR3902).
3.2lbs
Secondary: 250-0-250 V100 mA
Filament winding 1: 5 V2 A
Filament winding 2: 6.3 V3 A
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 12V / 24V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 24 V series, 12 V parallel secondary.
Please Log In to view prices